Vektorová analýza, rotační stabilita a vizuální výsledky po implantaci nové asférické torické IOL

Bi-Flex 677TA(Y) torickáVektorová analýza, rotační stabilita a vizuální výsledky po implantaci nové asférické torické IOL

Bachernegg A, Rückl T, Strohmaier C, Jell G, Grabner G, Dexl AK

PURPOSE:

To evaluate vector analysis, rotational stability, and refractive and visual outcome of a new toric intraocular lens (IOL) for correction of preexisting corneal astigmatism during routine cataract surgery.

METHODS:

In this prospective, interventional case series, 30 toric, aspheric Bi-Flex T toric IOLs (Medicontur Medical Engineering Ltd., Inc., Zsámbék, Hungary) were implanted in 20 consecutive patients with topographic corneal astigmatism between 1.50 and 4.00 diopters (D) and evaluated within the first year after implantation. Appropriate IOL-toric alignment was facilitated by combined imaging/eye tracking technology. Postoperative evaluation included refraction and uncorrected and corrected distance visual acuities (UDVA, CDVA). For each visit, photodocumentation in retroillumination was performed to evaluate toric alignment and potential toric IOL rotation. Vector analysis of refractive astigmatism was performed using the Alpins method.

RESULTS:

At 12 months postoperatively, a reduction of the refractive astigmatism from 1.93 ± 0.90 D (range: 0.50 to 4.00 D) to 0.28 ± 0.61 D (range: 0.00 to 1.50 D) could be found, with patients achieving a mean UDVA of 0.06 ± 0.16 logMAR (range: −0.18 to 0.40 logMAR; Snellen 20/20). Intraoperative to 12-month postoperative comparison of IOL axis alignment showed low levels of rotation (0.2° ± 2.41°; range: +4° to −5°). Vector analysis showed target induced astigmatism of 0.60 D @180°, surgically induced astigmatism of 0.80 D @177°, correction index of 1.02 ± 0.25, and a difference vector of 0.30 D @82°.

CONCLUSIONS:

Implantation of the new Bi-Flex T IOL was a safe, stable, and effective method to correct preexisting regular corneal astigmatism during cataract surgery.

PODOBNÉPUBLIKACE

Tyto stránky jsou určeny odborným pracovníkům ve zdravotnictví. Informace nejsou určeny pro laickou veřejnost. Potvrzuji, že jsem odborníkem ve smyslu §2a Zákona č. 90/2021 Sb., o regulaci reklamy, ve znění pozdějších předpisů, čili osobou oprávněnou předepisovat léčivé přípravky nebo osobou oprávněnou léčivé přípravky vydávat. Beru na vědomí, že informace obsažené dále na těchto stránkách nejsou určeny laické veřejnosti, nýbrž zdravotnickým odborníkům, a to se všemi riziky a důsledky z toho plynoucími pro laickou veřejnost.